CAMAC Crates Load for AMANDA-DAQ.


Status January, 1998.

Below a summary table on the current load of the different CAMAC Crates in use with the AMANDA-DAQ before implementation of the new DAQ, as measured January 8th, 1998.
Changes in loads will be minor due to the changes in Feb. 1998, so this gives the rough picture for the new DAQ98 as well. Note, there are is the new Wiener Crate added since Feb. 1998.

Measured Current in Ampere.

Rack.Crate

Crate-Type

Modules

+6 V

I in A

-6 V

I in A

+12 V

I in A

-12 V

I in A

+24 V

I in A

-24 V

I in A

5.1

3.1

3.2

3.3

3.4

LCR-8025

LCR-8025

LCR-8025

LC-1434A

KinSys-1525

7x4413, 7x3412

6x3377, 9x7164

5x3377, 10x7164

1x4413, 5x3412

7x4413, 7x3412

22

40

41

9

17

50

32

33

15

43

.03

.04

.04

0.

0.

.02

.02

.01

0.

0.

0.7

5.0

5.3

0.17

0.4

1.0

1.9

1.5

0.22

0.5


Status November 3rd, 2000.

Current load of the different CAMAC Crates in use with the AMANDA-DAQ before as of November, 2000.

Measured Current in Ampere.

Rack.Crate

Crate-Type

Modules

+6 V

I in A

-6 V

I in A

+12 V

I in A

-12 V

I in A

+24 V

I in A

-24 V

I in A

3.1

3.2

3.3

5.1

6.2

6.3

Snmp.1

Snmp.2

LCR-8025

LCR-8025

DSP

KinSys

Wiener

Wiener

Maxima885

LC-1434A

DAQ#1/TDC/ADC/..

DAQ#2/TDC/ADC/..

DISC-4413/3412

DAQ#3/12*ADC

Dead (was DAQ#3)

DAQ#4/11*ADC

SNMP-SN

SNMP-GRB/off

33.

35.9

3.8

32.

-

28.3

16

8.1

28.2

30.2

8.4

22.

-

19.6

3.

1.9

.01

.02

.0

.0

-

-

.0

.0

.03

.02

.0

.0

-

-

.0

.0

5.1

5.3

.11

6.2

-

5.4

.02

.0

5.0

1.5

0.12

.0

-

.0

.01

.0